Main Feature:
1. It is installed with close-table graphical colorful LCD touch screen and wireless remote control exposure, which makes the operator easy to use.
2. We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.
3. It can choose KV, mAs two buttons system photograph mode and Kv, mA, S three buttons system, two photography mode could meet different users professional requirements perfectly
4. Adopt the technology of kV and mAs numeral closed loop control, real-time control of the microprocessor, which ensures the accuracy and repeatability of the output dose.
5. Be equipped with radiography parameter of multi-part, multi-posture, multi-body, adult -child physical characteristic, the operator can modify and save the parameter by himself, which makes the operation more conveniently.
6. First high power combined high frequency high voltage X-ray source and high frequency inverter power supply, which can reduce energy loss from outside HV generator and cable. It makes good quality X-ray, beautiful appearance and convenience.
7. Possess multiple automatic protection and fault clue function, which makes the operation safer and more reliable.
8. The radiography table can float in any direction, electromagnetic braking, position the patient more convenience and accuracy.
9. X-ray generator component can move round the axis of X-ray generator, cross arm and Pillar stand , be convenient with side and slanting direction projection and radiography of patient on the stretcher.
10. Be equipped with the chest stand, which is used in the radiography of the head, chest, belly, pelvic cavity, backbone and periphery.
11. Control console of graphic program controlled LCD touch screen is optional, which can set the radiography parameter and exposure in another room.
Item | content |
Output power | 55kW |
Main inverter frequency | 60kHz |
X-ray tube (SIEMENS RAY®-14_1) |
Rotary anode, dual-focus, large focus: 1.2mm, small focus: 0.6mm, the frequency for large is 78kW and small is 33kW. Anode thermal capacity:260kJ (370kHu) Tube thermal capacity: 1000kJ (1780kHu) |
Rotary anode speed | 8500rpm-10800rpm |
mA range | 10mA-500mA |
Tube voltage | 40kV-150kV |
Anode target surface angle | 12° |
mAs | 0.1-630mAs |
Table radiography grids | Grid density:103L/INCH;Grid ratio:10:1;Focusing distance:120cm;Stationary type:15"×18" |
Exposure Time | 0.001s-12.5s |
Power supply | 380/400VAC three phase, 50Hz. |
Operation method | close-table graphic program controlled LCD touchable screen operation; wireless remote control exposure |
Table size | 2000×760mm |
Table height | ≤700mm |
Table transverse movement | ≥220mm |
Table longitudinal movement | ≥900mm |
Grids cassette holder movement | ≥560mm |
X-ray tube assembly center rotation | ≥±120° |
Rotation of the pillar | 4×90° |
Axial rotation | 0-35° |
SID | 450-1200mm |
Pillar movement along the table | ≥1370mm |
Film size in grids cassette | Max 356mmX432mm(14''x17'') |