Shop

Filters

Price
N
N
Reset
WALK-IN FUME HOOD (FH1800(W) 220V
BIOLOGICAL SAFETY CABINET, WALK IN FUME HOOD

WALK-IN FUME HOOD (FH1800(W) 220V

Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Product Feature

1.    Operators are available to walk into the fume hood to operate if need.

2.    Large room exhaust system, suitable for large laboratory instruments and equipment.
Technical Tarameters

Model

FH1200(W)

FH1500(W)

FH1800(W)

External Size (W*D*H)

1200*800*2200mm

1500*800*2200mm

1800*800*2200mm

Internal Size (W*D*H)

980*600*1650mm

1280*600*1650mm

1580*600*1650mm

Max Opening

1300mm

Exhaust Airflow Volume

1150m3/h

1500m3/h

1850m3/h

Inflow Air Velocity

0.3~0.8m/s

Noise

62dB

Vibration

XYZ direct ≤4μm

Illumination

≥800Lux

Fluorescent Lamp

12W*2

16W*2

16W*2

Power Supply

AC220V±10%, 50/60Hz;110 V±10%, 60Hz

Consumption

400W

600W

800W

Front Window

Manual, Toughened glass

Material

 

Exterior

1.0mm cold-rolled steel with bacteria powder coating.

Interior

High grade melamine board with good acid and alkali resistance function

 

Standard Accessory

 

Blower( External) ,LED lamp, Water tap, Gas tap, PP cup sink, Remote control water valve, Remote control gas valve, Waterproof sockets * 4,4 meters PVC exhaust duct

Sockets

Total load of 4 waterproof sockets: ≤500W

Package Size(W*D*H)

mm/Gross

Wight

Main body

1410*1050*2430/240kg

1710*1050*2430/280kg

2010*1050*2430/330kg

Exhaust Blower

 1040*890*710/60kg

1040*890*710/60kg

1040*890*710/60kg

N2,300,000.00
0
WALK-IN FUME HOOD (FH1500(W) 220V
BIOLOGICAL SAFETY CABINET, WALK IN FUME HOOD

WALK-IN FUME HOOD (FH1500(W) 220V

Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Product Feature

1.    Operators are available to walk into the fume hood to operate if need.

2.    Large room exhaust system, suitable for large laboratory instruments and equipment.
Technical Tarameters

Model

FH1200(W)

FH1500(W)

FH1800(W)

External Size (W*D*H)

1200*800*2200mm

1500*800*2200mm

1800*800*2200mm

Internal Size (W*D*H)

980*600*1650mm

1280*600*1650mm

1580*600*1650mm

Max Opening

1300mm

Exhaust Airflow Volume

1150m3/h

1500m3/h

1850m3/h

Inflow Air Velocity

0.3~0.8m/s

Noise

62dB

Vibration

XYZ direct ≤4μm

Illumination

≥800Lux

Fluorescent Lamp

12W*2

16W*2

16W*2

Power Supply

AC220V±10%, 50/60Hz;110 V±10%, 60Hz

Consumption

400W

600W

800W

Front Window

Manual, Toughened glass

Material

 

Exterior

1.0mm cold-rolled steel with bacteria powder coating.

Interior

High grade melamine board with good acid and alkali resistance function

 

Standard Accessory

 

Blower( External) ,LED lamp, Water tap, Gas tap, PP cup sink, Remote control water valve, Remote control gas valve, Waterproof sockets * 4,4 meters PVC exhaust duct

Sockets

Total load of 4 waterproof sockets: ≤500W

Package Size(W*D*H)

mm/Gross

Wight

Main body

1410*1050*2430/240kg

1710*1050*2430/280kg

2010*1050*2430/330kg

Exhaust Blower

 1040*890*710/60kg

1040*890*710/60kg

1040*890*710/60kg

N1,955,000.00
0
WALK-IN FUME HOOD (FH1200(W) 220V
BIOLOGICAL SAFETY CABINET, WALK IN FUME HOOD

WALK-IN FUME HOOD (FH1200(W) 220V

Fume Hood is used to protect lab environment and operator during general chemical applications. It actively protects operator from inhaling toxic vapors and dramatically reduces the risk of fire and explosion. By installing proper filter, it can also protect environment.
Product Feature

1.    Operators are available to walk into the fume hood to operate if need.

2.    Large room exhaust system, suitable for large laboratory instruments and equipment.
Technical Tarameters

Model

FH1200(W)

FH1500(W)

FH1800(W)

External Size (W*D*H)

1200*800*2200mm

1500*800*2200mm

1800*800*2200mm

Internal Size (W*D*H)

980*600*1650mm

1280*600*1650mm

1580*600*1650mm

Max Opening

1300mm

Exhaust Airflow Volume

1150m3/h

1500m3/h

1850m3/h

Inflow Air Velocity

0.3~0.8m/s

Noise

62dB

Vibration

XYZ direct ≤4μm

Illumination

≥800Lux

Fluorescent Lamp

12W*2

16W*2

16W*2

Power Supply

AC220V±10%, 50/60Hz;110 V±10%, 60Hz

Consumption

400W

600W

800W

Front Window

Manual, Toughened glass

Material

 

Exterior

1.0mm cold-rolled steel with bacteria powder coating.

Interior

High grade melamine board with good acid and alkali resistance function

 

Standard Accessory

 

Blower( External) ,LED lamp, Water tap, Gas tap, PP cup sink, Remote control water valve, Remote control gas valve, Waterproof sockets * 4,4 meters PVC exhaust duct

Sockets

Total load of 4 waterproof sockets: ≤500W

Package Size(W*D*H)

mm/Gross

Wight

Main body

1410*1050*2430/240kg

1710*1050*2430/280kg

2010*1050*2430/330kg

Exhaust Blower

 1040*890*710/60kg

1040*890*710/60kg

1040*890*710/60kg

N1,840,000.00